LH Series | LH-1.5 | LH-6 | LH-10 | BHD-500 | BHD-400 | BHD-200
HD-500 | HD-400 | HD-200 | SHD Series
We supply Temperature/Humidity Chambers to program controlled conditions of combined Temperature and Relative Humidity. All Chamber Components offer maximum resistance to the corrosive effects of moisture combined with extreme conditions. Consult our Design Engineering services for special temperature and humidity conditions.
Model | Size | Dimensions H x W x D |
Standard #1. 0° to +94°C (+32°F to +200°F) Optional #2. -20°C to +94°C (-4°F to +200°F) |
LH-1.5 | 1.5 Cubic Ft. | Internal 13" x 14" x 13" External 33" x 27" x 26" |
20% to 98% ±2% RH As limited by a +2°C dew point |
LH-6 | 5.8 Cubic Ft. | Internal 24" x 20" x 18" External 46" x 33" x 31" |
Temperature: ±.5°C at the sensor Humidity: ±2% RH at the sensor |
110/120 Volt 50/60 Hz. |
|||
LH-10 | 10 Cubic Ft. | Internal 30" x 24" x 24" External 52" x 36" x 37" |
Manual two channel microprocessor based digital set - Digital indicating controller temperature in °C or °F - Humidity direct RH |
Standard Features | Optional Extras |
|
|
The BHD-500 Series use a single-stage mechanical refrigeration system that can produce dry bulb temperatures down to 35°F/-37°C.
The BHD-200 Series produces dry-bulb temperatures down to -100°F/-73°C.
Model | Working Volume |
Dimensions H x W x D |
Temperature Range |
Rise Time |
Pull
Down Time |
Humidity Range |
Power Requirements |
BHD-403 | 3 Cubic Ft. | Internal 16" x 20" x 18" External 28" x 49" x 28" |
-17°C to +177°C -0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 25 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-405 | 5 Cubic Ft. | Internal 20" x 20" x 22" External 32" x 49" x 32" |
-17°C to +177°C -0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 25 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-408 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 34" x 53" x 34" |
-17°C to +177°C -0°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 25 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-503 | 3 Cubic Ft. | Internal 16" x 20" x 18" External 28" x 49" x 28" |
-37°C to +177°C -35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-505 | 5 Cubic Ft. | Internal 20" x 20" x 22" External 32" x 49" x 32" |
-37°C to +177°C -35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-508 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 34" x 53" x 34" |
-37°C to +177°C -35°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-203 | 3 Cubic Ft. | Internal 16" x 20" x 18" External 28" x 49" x 28" |
-65°C to +177°C -85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 70 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-205 | 5 Cubic Ft. | Internal 20" x 20" x 22" External 32" x 49" x 32" |
-65°C to +177°C -85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 70 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
BHD-208 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 34" x 53" x 34" |
-65°C to +177°C -85°F to +350°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 70 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. 1 Phase 200 Volt 50 Hz. |
Standard Features | Optional Extras |
|
|
Model | Working Volume |
Dimensions H x W x D |
Temperature Range |
Rise Time |
Pull Down Time |
Humidity Range |
Power Requirements |
HD-405 | 5 Cubic Ft. | Internal 20" x 22" x 20" External 69" x 31" x 44 " |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-408 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 70" x 33" x 48" |
-17°C
to +200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-410 | 8 Cubic Ft. | Internal 28" x 24" x 27" External 71" x 33" x 52" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-413 | 13 Cubic Ft. | Internal 28" x 28" x 28" External 71" x 37" x 52" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-421 | 21 Cubic Ft. | Internal 32" x 32" x 32" External 76" x 41" x 54" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-427 | 27 Cubic Ft. | Internal 36" x 36" x 36" External 81" x 54" x 74" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-432 | 32 Cubic Ft. | Internal 38" x 38" x 38" External 83" x 56" x 76" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-449 | 49 Cubic Ft. | Internal 42" x 42" x 44" External 87" x 60" x 82" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-464 | 64 Cubic Ft. | Internal 48" x 48" x 48" External 95" x 70" x 85" |
-17°C to
+200°C -0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 20 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-505 | 5 Cubic Ft. | Internal 20" x 22" x 20" External 69" x 31" x 44" |
-37°C to
+200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-508 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 70" x 33" x 48" |
-37°C
to +200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-510 | 10 Cubic Ft. | Internal 28" x 24" x 27" External 71" x 33" x 52" |
-37°C
to +200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-513 | 13 Cubic Ft. | Internal 28" x 28" x 28" External 71" x 37" x 52" |
-37°C
to +200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-521 | 21 Cubic Ft. | Internal 32" x 32" x 32" External 76" x 41" x 54" |
-37°C
to +200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-527 | 27 Cubic Ft. | Internal 36" x 36" x 36" External 81" x 54" x 74" |
-37°C to
+200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-532 | 32 Cubic Ft. | Internal 38" x 38" x 38" External 83" x 56" x 76" |
-37°C to
+200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-549 | 49 Cubic Ft. | Internal 42" x 42" x 44" External 87" x 60" x 82" |
-37°C to
+200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-564 | 64 Cubic Ft. | Internal 48" x 48" x 48" External 95" x 70" x 85" |
-37°C to
+200°C -35°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 35 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-205 | 5 Cubic Ft. | Internal 20" x 22" x 20" External 69" x 31" x 44" |
-65°C to
+200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20% to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-208 | 8 Cubic Ft. | Internal 24" x 24" x 24" External 70" x 33" x 48" |
-65°C
to +200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 70 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-210 | 10 Cubic Ft. | Internal 28" x 24" x 27" External 71" x 33" x 52" |
-65°C
to +200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
1 Phase 220 Volt 60 Hz. |
HD-213 | 13 Cubic Ft. | Internal 28" x 28" x 28" External 71" x 37" x 52" |
-65°C
to +200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-221 | 21 Cubic Ft. | Internal 32" x 32" x 32" External 76" x 41" x 54" |
-65°C
to +200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20%
to 98% ±2% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-227 | 27 Cubic Ft. | Internal 36" x 36" x 36" External 81" x 54" x 74" |
-65°C to
+200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-232 | 32 Cubic Ft. | Internal 38" x 38" x 38" External 83" x 56" x 76" |
-65°C to
+200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-249 | 49 Cubic Ft. | Internal 42" x 42" x 44" External 87" x 60" x 82" |
-65°C to
+200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
HD-264 | 64 Cubic Ft. | Internal 48" x 48" x 48" External 95" x 70" x 85" |
-65°C to
+200°C -85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes | Room ambient to lower limit in approx. 60 minutes | 20% to 98% ±3% RH limited by +2°C dew point |
3 Phase 220 Volt 60 Hz. |
Standard Features | Optional Extras |
|
|
MODEL |
SIZE |
DIMENSIONS |
SHD-410 SHD-510 SHD-210 |
10 cubic Feet | 40" x 24" x 21" 52" x 60" x 32" |
SHD-416 SHD-516 SHD-216 |
16 cubic Feet | 48" x 24" x 30" 58" x 60" x 40" |
SHD-431 SHD-531 SHD-231 |
31 cubic Feet | 60" x 30" x 30" 72" x 74" x 40" |
SHD-4110 SHD-5110 SHD-2110 |
110 cubic Feet | 60" x 52" x 60" 81" x 122" x 80" |
Temperature Range: | 400
Series Models: -17°C to +94°C (0°F to+200°F) 500 Series Models: -37°C to +200°C (-35°F to +392°F) 200 Series Models: -65°C to +200°C (-85°F to +392°F) |
Humidity Range: | 10% to 98% ±2% RH limited by ±2°C dew point |
Accuracy: | Temperature:
± .25°C at the sensor Humidity: ±2% RH at the sensor |
Temperature Pull-Down | 400 Series Models: Room ambient to lower
limit in approximately 25 minutes. 500 Series Models: Room ambient to lower limit in approximately 45 minutes. 200 Series Models: Room ambient to lower limit in approximately 60 minutes. |
Temperature Rise Time | Room ambient to lower limit in approximately 20 minutes. |
Power Requirements | 220 Volts 3 Phase 60Hz. (Standard) 208 Volts 3 Phase 60Hz. or 460 Volts 3 Phase 60Hz. (Available) |
Standard Features |
|
|
*Dimensions maximum with largest refrigeration system. Smaller footprint with different systems.
**Full glass door available to -17°C only. Below -17°C equipped with full metal door with smaller window. |